Lack of pressure in TITAN, block of pump handle
Service007 - lack of pressure in TITAN, block of pump handle
Symptom:
Block of pump handle, the handle cannot be moved in any direction.
Reason:
Probably the rubber valve balls have swollen in contact with aggressive chemicals in the sprayer` s pump.
Marolex have eliminated this problem by introducing, in March 2006, balls made of technical glass / (GVS - System).
Solution:
Demount the pump unit by removing the lever tie(T20) from the pump and unscrewing the pump nut. Remove the pump unit and the mixer, disassembly the pump into two parts: white element (T24 pump cover) and black element (T5 pump). Unscrew the nuts from these elements (T16 and T15) under which the balls are placed. Replace the rubber balls with glass ones and mount the pump - follow the above instructions in reverse order. While mounting back the pump smear the O-ring (T11) with silicone smear (Z06)
Concern series:
Titan 12, 16, 20